Commercial HVAC across Kingfisher, Canadian, Oklahoma, Garfield, Major, Logan and Blaine counties. Call 405-375-4822

Commercial VRF · Oklahoma

LG VRF Systems in Oklahoma

4.8 stars, 300+ Google reviews

If you run a care facility, a church, a school or an office with a lot of rooms, a pile of separate units gets old fast. A VRF system can be the cleaner answer. I am Dave Hartzell, a Master HVAC technician with 47 years in the trade, and I have installed one of these myself. I buy, install and service LG Multi V VRF systems, and I trained on the LG Multi V5 platform.

What VRF means, in plain words

VRF stands for variable refrigerant flow. One outdoor unit feeds many indoor units, and the system changes how much refrigerant each indoor unit gets. Each room can ask for what it needs.

Heat recovery (3-pipe) or heat pump (2-pipe)

A heat pump VRF has two pipes. The whole system heats or the whole system cools, one at a time.

A heat recovery VRF has three pipes. That lets one zone heat while another zone cools, at the same moment. In a building where a sunny office and an interior hallway want different things, that matters. The LG Multi V5 I installed is the 3-pipe heat recovery kind.

Who it fits

  • Care facilities, where residents and staff feel the temperature differently
  • Churches with a sanctuary, classrooms and offices under one roof
  • Offices and schools with many rooms on one system
  • Any multi-room building where separate units would crowd the roof or the walls

What an install involves

  1. Old equipment comes out of the mechanical room.
  2. The outdoor unit goes on a rooftop rack.
  3. Indoor units, such as 4-way ceiling cassettes, are hung and the copper is run to each one.
  4. Every line gets a pressure test.
  5. I pull a vacuum and watch it on a micron gauge until it is dry and tight.
  6. Startup, with the manufacturer’s tech support on the line.

I walk through a real one on my LG Multi V5 care facility project page.

Why evacuation and pressure testing matter

A VRF has far more copper than a home system, and every joint is a place for a leak. Moisture or air left in those long lines shortens equipment life. So I pressure test first, then evacuate and watch the micron gauge. On the Kingfisher job the gauge read 43 microns. I do not let refrigerant in until the numbers say the system is ready.

Service on a VRF system

A commercial diagnostic is $389 flat, day or night, on light commercial equipment up to 15 tons. Larger equipment is sized by the tech on site. Repairs are quoted in writing before I start.

When I look at a VRF problem, I check:

  • Fault codes on the indoor and outdoor controls
  • Refrigerant charge and line condition
  • Outdoor unit operation, including the control board
  • Each indoor unit, condensate drain and airflow
  • Electrical supply and communication between units

Maintenance agreements on commercial buildings are priced one-to-one after I see the building and the equipment. There is no flat plan price.

Have a building that needs a VRF system?

Tell me about the building and I will tell you straight what fits.

Call 405-375-4822

Questions about LG VRF in Oklahoma

How much does LG VRF service cost in Oklahoma?

A commercial diagnostic is $389 flat, day or night, on light commercial equipment up to 15 tons. That covers me coming out and finding what is wrong. Repairs are quoted in writing before I start. Call 405-375-4822.

What is the difference between heat recovery and heat pump VRF?

A heat pump VRF uses two pipes and the whole system heats or cools at one time. A heat recovery VRF uses three pipes, so one room can heat while another cools. Heat recovery fits buildings where rooms need different things at the same time.

What kind of buildings use a VRF system?

Care facilities, churches, offices, schools and other buildings with many rooms that each need their own temperature. One outdoor unit feeds many indoor units, so you skip a pile of separate systems.

Do you install and service LG Multi V VRF in Oklahoma?

I install and service LG Multi V VRF systems. I put in a Multi V5 heat recovery system at a Kingfisher care facility in 2021. Call 405-375-4822 and tell me about your building.

Why does evacuation matter on a VRF install?

A VRF has a lot of copper line, and any moisture or air left inside hurts the system. I pressure test every line, then pull a deep vacuum and watch it on a micron gauge before refrigerant goes in.

More on what I do for commercial buildings is on my commercial HVAC page, and you can see other jobs on my HVAC projects page.

Scroll to Top
Recent Jobs · 6,500+ Jobs Done
Call 405-375-4822 Book Online