15+ years • 6,500+ jobs completed • 1,500+ Oklahoma homes served

Commercial HVAC for The Cedar Gate Event Venue, Loyal, Oklahoma

I designed and installed the whole heating and cooling system for The Cedar Gate, an event venue out on Co Rd N2740 near Loyal in Kingfisher County, Oklahoma, a custom Carrier dual-fuel setup with the units and ductwork hung up between the trusses, zoned so the kitchen, the bathrooms, the main hall, and the storage all run on their own, and I have been the shop servicing that building since.

4.8 stars / 300+ reviews  |  Master HVAC License  |  Commercial HVAC  |  BBB A+

The main event hall at The Cedar Gate venue near Loyal, Oklahoma with a stone fireplace and open floor before the new commercial HVAC system went in, serviced by Hartzell's Heat and Air
The main hall at The Cedar Gate near Loyal, the room I had to keep comfortable for a crowd.

The Job

The Cedar Gate is an event venue out in the country near Loyal, Oklahoma, the kind of place people book for a wedding, a reception, or a big gathering. A building like that is built to fill up with people, and when a hundred or two hundred folks are inside on a hot August evening, the air has to stay cool, clean, and moving, or the whole event suffers. That is not a comfort problem you fix after the fact. It has to be designed in from the start.

So I designed the system around the way the building gets used. The Cedar Gate runs on a custom Carrier dual-fuel design, with the air handlers and the ductwork hung up in the open between the wood trusses instead of buried in an attic. I split the building into independent zones, the kitchen on its own, the bathrooms and storage on their own, the main hall on its own, and the golf cart storage on its own, so each space holds its own temperature and the rooms with water in them stay protected when it drops below freezing. The design pulls in fresh outdoor air for the people inside, so the room does not go stale when it fills up.

This is light commercial work, not a house. A venue this size takes a real load calculation, multiple systems, zoned controls, and a crew that can hang equipment and run duct in an open truss ceiling and make it look right. I have been doing this kind of work for 47 years, and I ran a year of national-chain commercial accounts in Dallas before I came back home to Kingfisher and opened my own shop.

Carrier commercial condensing units being delivered on a box truck for the new HVAC system at The Cedar Gate event venue near Loyal, Oklahoma, installed by Hartzell's Heat and Air
The Carrier condensing units arriving at the site near Loyal during the install.

Why Dual-Fuel, and Why Zoned

A venue out in the country has two problems a regular house does not. It runs on propane and a generator, not city gas and unlimited power, and it sits empty between events and then fills wall to wall for a few hours. A dual-fuel design answers both. Half the building runs on a heat pump in milder weather and low occupancy, which is cheaper to run and lets the place operate on a smaller generator, and switches over to gas heat when it gets cold outside. That keeps the propane bill and the electric load down without ever leaving the building too cold.

The zoning is the other half of it. A kitchen throws heat, a packed main hall throws heat, and an empty storage room needs almost nothing. By giving each one its own system and its own thermostat, the room people are standing in gets exactly what it needs, and the room nobody is in is not wasting fuel. The bathrooms and the storage with water lines stay on through a freeze so nothing bursts when the building sits empty in January.

Carrier HVAC equipment staged on pallets inside the open main hall at The Cedar Gate event venue near Loyal, Oklahoma, with exposed wood trusses overhead, during a Hartzell's Heat and Air commercial install
The Carrier equipment staged in the main hall before we hung it between the trusses.

Equipment Installed

  • Carrier 16 SEER heat pumps, model CH16NA060P0G, on the dual-fuel zones. The heat pump carries the building in milder weather and low occupancy, so the place runs cheaper and on a smaller generator.
  • Carrier 95% propane gas furnaces, model 59SC5B100E21–20, for the gas side of the dual-fuel zones and the AC-plus-gas zones, so the building has real heat when it gets cold.
  • ADP horizontal coils matched to the systems, set up to hang in the open between the trusses with the air handlers.
  • Independent zoning with its own thermostat per area, kitchen, bathroom and storage, main hall, and golf cart storage, so each space holds its own temperature.
  • Fresh-air intake for the occupants, secondary drain pans with safety float switches and secondary drain shutoffs, a new main drain line, and a 2-inch filter system.

Note: these brand and model facts come straight off the job record. The exact model and serial live on the unit nameplates on site. If you need a full nameplate string for a facility file or a warranty, call me and I will pull it.

On Site

Commercial air handler and ductwork hung between the wood trusses at The Cedar Gate event venue near Loyal, Oklahoma during a Hartzell's Heat and Air dual-fuel HVAC installation
An air handler and ductwork hung up in the open between the trusses, the way this building was designed.
Hartzell's Heat and Air technician on a ladder installing ductwork between the ceiling trusses at The Cedar Gate event venue near Loyal, Oklahoma
My crew running duct between the trusses at The Cedar Gate.

Why It Mattered

A venue is not really about the equipment. It is about the people in the room. When a family books The Cedar Gate for a wedding, they are not thinking about the HVAC, and that is the point. The room should just be comfortable, the air should stay fresh while a crowd is in it, and nobody should be fanning themselves with a program or stepping outside to cool off. I built this system so the building can fill up with people and still feel good, because that is what the owner is actually selling, a comfortable place to gather.

The health side matters too. Pack a building with people and the air goes stale fast, so I designed in real fresh-air intake and a 2-inch filter system to keep what everyone is breathing clean. And because it is a venue that sits empty between events, the freeze protection on the bathrooms and the water areas means the owner is not walking into a burst pipe after a cold snap. I treat a job like this the same way I treat my neighbors here in Kingfisher: figure out how the building actually gets used, build it right the first time, and stand behind it after.

Event venue, restaurant, shop, or office, I design and install commercial HVAC that fits how the building gets used. Call 405-375-4822.

Commercial HVAC FAQ

Do you design and install HVAC for event venues and commercial buildings in Oklahoma?

Yes. I designed and installed the full heating and cooling system for The Cedar Gate event venue near Loyal, and I handle event venues, restaurants, shops, and offices across central and western Oklahoma. I do the load calculation, the equipment, the zoning, and the ductwork, and I keep the building running after the install. I serve Kingfisher, Canadian, Oklahoma, Garfield, Logan, Major, and Blaine counties.

What is a dual-fuel HVAC system, and why use one at a rural venue?

A dual-fuel system pairs a heat pump with a gas furnace. The heat pump carries the building in milder weather and low occupancy, which is cheaper to run and lets the place operate on a smaller generator, and it switches to gas heat when it gets cold outside. For a venue out in the country on propane and a generator, like The Cedar Gate near Loyal, that keeps the propane bill and the electric load down without ever leaving the building too cold.

Can you zone a building so different rooms hold different temperatures?

Yes. At The Cedar Gate I split the building into independent zones, the kitchen on its own, the bathrooms and storage on their own, the main hall on its own, and the golf cart storage on its own, each with its own system and thermostat. That way the room full of people gets exactly what it needs, the empty room is not wasting fuel, and the areas with water lines stay protected through a freeze.

How do you keep the air fresh when a venue fills up with people?

I design in a fresh-air intake that pulls in outdoor air for the occupants, so the room does not go stale when it fills up, and I set up a 2-inch filter system to keep the air clean. Pack a building with a crowd and the air turns over fast, so fresh air and real filtration are part of the design, not an afterthought. That is the health side of comfort, and it matters in a room full of guests.

What does a commercial HVAC system for an event venue cost in Oklahoma?

Commercial work is priced by the job, not a flat sticker, because a venue install is a custom design, multiple systems, zoned controls, and ductwork, not one box swapped for another. I give a free written estimate for new equipment once I have seen the building and run the load. Oklahoma utility rebates may apply, and financing is available through Synchrony, Wells Fargo, Wisetack, Klarna, and JB Financing.

Have a commercial or event-venue HVAC job in Central Oklahoma?

New design, multiple zones, dual-fuel, or routine commercial service, I can handle it. Free estimates on new equipment.

Call 405-375-4822

or book at hartzellsheatair.com  |  Commercial HVAC

Scroll to Top
Our Work · 6,500+ Jobs Done
Call 405-375-4822 Book Online