House won’t cool? Straight answer, fast.
Oklahoma heat finds the weak part: a capacitor, a dirty outdoor coil, a plugged drain, a tired blower motor. I find which one it is, put the price in writing, and fix it once.
4.8 stars · 300+ Google reviews · Same day where the schedule allows · Se habla español
Dave Hartzell, owner of Hartzell’s Heat & Air, 602 S Main St, Kingfisher. I hold an Oklahoma Master HVAC license and IGSHPA accreditation for geothermal, my techs are NATE certified, and I am a Trane Comfort Specialist (TCS SELECT) dealer and a Mitsubishi Diamond Dealer. 47 years in the trade, and 15+ years running my own shop in Kingfisher.
Last updated September 23, 2026.
The problems I see every Oklahoma summer
- Running, but not coolingUsually charge, airflow or a failed capacitor. Why it happens
- Capacitor or contactor failureThe most common single repair in the heat.
- Ice on the lines or coilLow airflow or low charge freezes the evaporator.
- Refrigerant leakFound, repaired and recharged to spec. Never just topped off.
- Runs all day, never hits setpointDirty coil, losing charge, or undersized from the start.
- Blower or condenser fan outBoth motors fail more in sustained heat.
- Water on the floorA clogged condensate drain or a float switch shutting it down.
- Thermostat, board or breaker faultsWiring, disconnects and control boards.




Running, but not cooling
Same system, two different days. On the left of the cycle the coil is clean and the charge is right, so the air coming out of your register is cold. On the right the outdoor coil is packed or the charge is low, the compressor keeps running, and the air comes back warm. That is the call I run most in July.
What happens when I get there
- The easy things firstThermostat, filter, breaker, outdoor disconnect. The equipment stays closed until those are ruled out.
- Electrical under loadCapacitor microfarads, contactor pitting and coil voltage, compressor amp draw. If the capacitor failed, I check whether the compressor took it out.
- Refrigerant on calibrated gaugesSuperheat and subcooling against the maker’s spec. Leaks get found and repaired under EPA Section 608 rules.
- Airflow and coilsStatic pressure, blower speed and amps, evaporator and condenser coil condition.
- Written price, then you decideYou know the number before I touch a wrench.



How much does AC repair cost in Kingfisher, Oklahoma?
Typical installed ranges. Your exact price is confirmed on site, in writing, before work starts.
✦ Repair menu ✦
6-month labor guarantee on the part I replaced · Financing covers repairs too
What I would do if it were my house
Under 10 years old and the repair is less than half the cost of replacing: repair it. Past 15 years with repeat failures or a dead compressor: replacing usually wins. I do not make more money steering you to a new system.
Repair
Fix the failed part, confirm the rest of the system is healthy, get you cool today.
Service call $210 flatRebuild
New compressor, coil and refrigerant circuit, keep the rest. Adds 8 to 10 years for a fraction of a new system.
$3,500 to $5,500 installedHow a rebuild worksReplace
I come look at the house and the ductwork before anybody talks about a price.
Estimate freeReplacement optionsAlready holding someone else’s quote? Get a second opinion on a replacement quote or run the repair or replace calculator.
Trane and Mitsubishi, factory trained

Trane Comfort Specialist (TCS SELECT) dealer
Factory trained and recertified every year, with dealer access to ComfortLink II fault codes. I read XV20i, XV18, XR16 and XR15 faults most shops cannot.

Mitsubishi Diamond Dealer
The tooling and training for M-Series and P-Series ductless, multi-zone and hyper-heat. Diamond Dealer installs qualify for a 12-year parts warranty.

Everything else
Carrier, American Standard, Lennox, Rheem, Goodman, Daikin and the rest. Parts for most brands ride on the truck.
What customers say
“Tim and Juan done an excellent job servicing my heatpump. We were really impressed of how thorough they checked everything.”
Steve I. · Google review · March 2026
“Juan, Tim and Carl are EXCELLENT at their job.”
Richard M. · Google review · March 2026
Diagnosed right the first time
I spent 12 years at Sammy’s Heat, Air & Sheet Metal in Watonga before I opened Hartzell’s about 15 years ago. Sammy ran a Carrier dealership, and he trained me to diagnose before I ever touched a wrench: find the root cause, not just the symptom, and be straight with the customer about what you found. That is still how I run AC calls in Kingfisher, Hennessey, Watonga, Okarche, Dover, Loyal, Cashion and every town in between.
My techs are paid a percentage of the completed invoice, so they have a personal stake in getting it right the first time, not in guessing wrong and coming back. Every repair carries my 6-month labor guarantee on the part I replaced. Parts carry their manufacturer’s warranty, and I buy parts with a 1-year warranty whenever one is available. If that part or my work on it fails within 6 months, I come back and fix it at no charge. A different part failing, or a leak in a different spot, is a new problem and a regular service call. Plenty of my customers are on their second and third system with me.
From my own job records: since 2017, when my current job system starts, I have 2,200+ completed jobs with a Kingfisher address, 450+ in Okarche, 280+ in Hennessey, 200+ each in Watonga and Dover, 140+ in Loyal and 100+ in Cashion. The years before 2017 are not in that system, so the real count is higher.
When replacing is the right call, I size the new system with an ACCA Manual J load calculation, not by copying the tonnage on the old unit.
Want to see it before you call? Watch my Ask Dave video on an AC that runs but will not cool, or read what I check on a pre-summer tune-up.
What I check before I give you a price
I work through the system in order: indoor unit first, then outdoor, then electrical and controls.
- Indoor unitEvaporator coil for freeze-up, dirt or damage. Blower motor and wheel: speed, amperage and airflow. Condensate drain for clogs and overflow risk. Filter and return air restriction. Refrigerant line temperatures, supply against return.
- Outdoor unitCondenser coil for dirt, bent fins and blocked airflow. Condenser fan motor and blade, amps and spin. Refrigerant pressures on both the high and low side. Compressor amp draw against its rated value. Electronic leak detection at the coil and fittings.
- Electrical and controlsCapacitor start and run microfarad readings. Contactor pitting, coil voltage and contact gap. Disconnect and breaker, fuse size and heat damage. Thermostat wiring and the call sequence. Safety controls: high pressure, low pressure and the float switch.
- Trane communicating systemsAs a Trane Comfort Specialist (TCS SELECT) dealer I can read ComfortLink II fault codes on communicating Trane equipment that most shops cannot, and I carry common Trane and RunTru parts on the truck.
Blower motor giving out? Most repair calls end up at the blower sooner or later. Old PSC motors run hot and burn out. You can put the same part back, or step up to a variable-speed ECM motor that runs quieter, uses less power and lasts longer. An OEM PSC replacement runs $1,912, a standard PSC blower motor $2,187, and an Azure ECM variable-speed upgrade $2,304 to $2,438. See the side-by-side.
Troubleshooting before you call? AC blowing warm air and what each HVAC noise means. Replacing soon? What the new A2L refrigerants cost.
Straight answers
How much does AC repair cost in Kingfisher, Oklahoma?
The service call is $210 flat: $99 dispatch plus $111 diagnostic. The repair itself is priced in writing before I start, and most common repairs run $150 to $850. The diagnostic is not credited toward the repair.
Why is my AC running but not cooling?
Most often a dirty filter, a frozen coil, low refrigerant from a leak, or a failed capacitor. I rule out the simple things first, then measure pressures and airflow to find the real cause.
How fast can you get here?
Same day where the schedule allows, and no-cool calls go first. Call and I will tell you the next open time straight rather than promise a window I cannot hold.
What does it cost after hours?
$309: $198 dispatch plus $111 diagnostic, for residential AC, heating and heat pumps. It is not refundable and is not credited toward the repair.
Can you work on an older R-22 system?
Yes. On an R-22 unit I look at condition and cost of ownership so you can choose between a repair now and a planned replacement later.
Do you work on geothermal in Kingfisher too?
Yes, and most of my geothermal work is right here. A geothermal diagnostic is $348 flat, weekday or after hours. What that visit covers.
Do you guarantee your AC repairs?
Yes. Every repair carries my 6-month labor guarantee on the part I replaced. Parts carry their manufacturer’s warranty, and I buy parts with a 1-year warranty whenever one is available. If it’s the same part, the same leak or my work, the callback is free. If it’s a different part, it’s a normal service call.
What do you check on an AC diagnostic?
The indoor coil, blower, drain, filter and line temperatures; the outdoor coil, fan, refrigerant pressures, compressor amps and leaks; and the capacitor, contactor, breaker, thermostat wiring and safety controls.
Should I replace my blower motor with an ECM?
If the old PSC motor failed, an ECM variable-speed upgrade runs quieter and lasts longer. It is $2,304 to $2,438 installed against $2,187 for a standard PSC motor.
How long has Hartzell’s been fixing AC in Kingfisher?
My shop at 602 S Main St has been open 15+ years, and I have 47 years in the trade. My job records since 2017 show 2,200+ completed jobs with a Kingfisher address, and the years before that are not in the system.
Tell me what it is doing
Warm air, ice on the lines, water on the floor, a hum with no fan. Describe it and I will tell you straight what I think it is before I drive out.
Call 405-375-4822Kingfisher, Hennessey, Okarche, Dover, Loyal, Cashion, Watonga and every town between. Counties: Kingfisher, Canadian, Oklahoma, Garfield, Major, Logan, Blaine.

